Email

inquiry@yukelab.com

Mob/whatsapp

0086 166 0175 7347

General Laboratory Instruments
LIST

Multifunctional Microplate Reader

YK-SM3600

Product Category: Microplate Reader

The YUKE YK-SM series of multifunctional grating-based microplate readers is widely used across fields such as organic chemistry, clinical diagnostics, drug screening, molecular biology, immunobiology, cell biology, biochemistry, environmental analysis, food safety testing, and materials science. Fully capable of replacing imported alternatives, this series stands as a leading domestic brand for high-performance microplate readers and represents a smart choice for research institutions and biochemical/pharmaceutical companies.


Products Detail Technical Parameter Feature And Application Download

Summary

The YUKE YK-SM series of multifunctional grating-based microplate readers is widely used across fields such as organic chemistry, clinical diagnostics, drug screening, molecular biology, immunobiology, cell biology, biochemistry, environmental analysis, food safety testing, and materials science. Fully capable of replacing imported alternatives, this series stands as a leading domestic brand for high-performance microplate readers and represents a smart choice for research institutions and biochemical/pharmaceutical companies.

 

The YUKE YK-SM3600 is a high-end, fully featured, modular multifunctional microplate reader utilizing a four-grating optical system. Engineered with premium components and detection modules to ensure stability and innovation, it meets the rigorous testing demands of drug R&D, life sciences, and other research sectors. It comes equipped with standard modules for absorbance, fluorescence, and chemiluminescence detection to satisfy routine experimental requirements.

 

To address diverse customer needs, the system offers high-end modular configuration options. This modularity allows customers to tailor the instrument to their specific budgets and requirements, ensuring the best possible cost-performance ratio and making it an ideal solution.


Key specifications of the YK-SM3600 model:

(1) General characteristics:n

* Temperature control: (Ambient + 2°C) to 65°C; temperature uniformity: ±0.2°C at 37°C;

n Shaking modes: Linear, cross, and orbital; shaking amplitudes: High, medium, and low;

n Plate formats: 6-well to 384-well (custom configurations available);

n Microplate analysis workstation with powerful data analysis capabilities;

n* Report output function: Supports export in various formats (PDF, HTML, RTF, DOCX, XLS, XLSX, CSV, Text, Image, etc.) to meet diverse customer needs; page colors and layouts are customizable;

n* Supports qualitative and quantitative analysis; includes a formula editor to meet various calculation requirements. The QC analysis function supports customizable color settings; QC display allows for the manual input of numerical values, symbols, and Chinese characters to meet diverse user needs;

(2) Absorbance performance:

n Light source: Xenon lamp

n Test modes: Photometric, kinetic, and spectral scanning

n Detector: Photocell

n *Wavelength range: 190 nm–1000 nm; wavelength accuracy: ±1.0 nm; wavelength repeatability: < 0.2 nm

n Linearity range: 0–4 Abs (96-well, 450 nm), ±2%

n *OD repeatability: CV < 0.5% @ 450 nm

n *Resolution: 0.0001 Abs

(3) Chemiluminescence performance:

n Test modes: Luminescence, kinetic, and spectral scanning

n *Detector: Photon-counting photomultiplier tube (PMT)

n Wavelength range: 300 nm–650 nm; scanning mode: 270 nm–850 nm

n Sensitivity: < 7 amol ATP/well

< 7 decades (flash ATP reaction)

n *Inter-well crosstalk: < 0.2% (white plate, values in the 10,000 range)

< 0.004% (white plate, values in the 1,000,000 range)

n *Test modes: Specific wavelength and photon counting (2 selectable modes)

n Optional upgrade: BRET function (filter-based mode)

(4) Fluorescence performance:

n Light source: Xenon lamp

n Detector: Photomultiplier tube (PMT)

n *Test modes: Fluorescence (top/bottom read), kinetic (top/bottom read), and excitation/emission spectral scanning (top/bottom read)

n *Excitation wavelength range: 190 nm–1000 nm; emission wavelength range: 270 nm–850 nm

n Wavelength resolution: 1 nm

n Wavelength bandwidth: Selectable 10 nm or 20 nm

n Fluorescence sensitivity:

Top read < 0.4 fmol (FITC/well → 384-well plate)

Bottom reading < 1 fmol (FITC/well → 384-well plate)

n Detection dynamic range:

Top reading > 6 orders of magnitude (FITC/well → 384-well plate)

Bottom reading > 5.5 orders of magnitude (FITC/well → 384-well plate)

n Optional FRET upgrade available (filter-based mode);

(5) Microscopy Imaging (optional):

n Plates and consumables: Microplates, glass slides, cell culture dishes, cell culture flasks, cell counting chambers

n Imaging modes: High-contrast brightfield, fluorescence, digital phase contrast

n Imaging methods: Monochromatic, multicolor, image stitching

n Light source: LED

n Camera: 16-bit scientific-grade grayscale CCD, 1.25 megapixels

n Color channels: Onboard 4-position interchangeable color module

n Objectives: 2-position fully automated objective turret; 2.5x, 4x, 10x, 20x, 40x, 60x objectives available

n Automation: Autofocus, auto-exposure, automatic LED intensity control

n Focusing methods: Image-based autofocus and laser-based autofocus

(6) Gas Control (optional):

n 0–20% CO2 control; 1–19% O2; adjustable O2 and CO2 concentrations;

(7) Dispenser Function (optional):

n Quantity: 2

n Dispensing volume: 10–1000 μL

(8) Fluorescence Polarization Performance (optional):

n Light source: Xenon lamp

n Sensitivity: 3 mP @ 1 nM fluorescein (typical application)

n Wavelength selection: Filters

(9) Time-Resolved Fluorescence Performance (optional):

n Light source: Xenon lamp

n Sensitivity: < 10 amol (Eu)

n Upgradable HTRF functionality; filter-based mode; equipped with a laser light source;

(10) AlphaScreen (optional):

n Wavelength selection: filters; excitation wavelength 680 nm; emission wavelength 400–660 nm

n < 100 amol/well P-Tyr-100 (using white 384-well plates)

(11) High-speed absorbance spectral module (optional):

n Detector: CCD

n Spectral scanning speed: 1 s/well

n Measurement range: 0–4 OD

n Wavelength range: 190–1000 nm

(12) Automated workstation (optional):

n Software: Supports custom protocol creation for fully automated operation;

n Robotic arm module: Capable of transferring microplates from the microplate reader to the plate stacker;

n Liquid dispensing module 1 (optional): Equipped with an automatic dispenser (20–200 μL or 100–1000 μL);

Liquid dispensing module 2 (optional): Upgradable configuration; fully automatic dispenser (10–1000 μL); dispensing volumes set via software (no manual operation required);

n Plate washer: 8-channel simultaneous washing;

n Plate stacker: Separates and stacks plates; one stacking module holds up to 20 microplates; additional stacking modules can be added as needed;

 


Main components of the YUKE YK-SM3600:

1. Main unit (including light source, detector, incubation system, and shaking system);

2. YUKE YK-SM3600 multifunctional microplate reader workstation software;


Download

keyword search:Multifunctional Microplate Reader

WELCOME TO YUKE

Do you want to Send Inquiry ?

Copyright © Shanghai Yuke Industrial Co., Ltd. All Rights Reserved.